How to improve the problem of high temperature rise of switching power supply transformer
In the working process of switching power supply transformers, engineers not only need to comprehensively consider the rationality of its design and structure, but also strictly control its temperature rise range, so as to avoid the problem of excessive temperature rise and reduced work efficiency. In the actual application process, the high temperature rise often occurs in the MOS tube of the power transformer and the transformer design itself. Today we will start from these two aspects and see how to effectively solve the temperature rise of the switching power transformer. too high problem.
First of all, from the perspective of the transformer itself, once the temperature rise is too high, it is mainly caused by four problems, namely copper loss, winding process problems, transformer iron loss and transformer design power is too small. No-load heating means the transformer insulation is damaged or the input voltage of the transformer is too high. If the insulation is damaged, the coil needs to be rewound. If the input voltage is high, the input voltage should be reduced or the number of coil turns should be increased. If the voltage is normal and it is hot and hot when the load is on, it means that the load of the power transformer is too large, and its load design needs to be changed.
In the design process of the switching power supply transformer, the heating situation of the MOS tube is the most serious, and the problem of its own high temperature rise is caused by the loss. The loss of the MOS tube consists of two parts: the switching process loss and the on-state loss. To reduce the on-state loss, the on-state loss can be reduced by selecting a low on-state resistance switch tube. The switching process loss is caused by the size of the gate charge and the switching time. Yes, reducing switching losses can be reduced by selecting devices with faster switching speeds and shorter recovery times. But what is more important is to reduce the loss by designing a better control method and buffering technology, such as the use of soft switching technology, which can greatly reduce this loss.
In addition, there is also a possibility that the temperature rise of the power transformer itself is too high, that is, the transformer itself is aging. When the engineer checks the transformer itself and the MOS tube and finds no abnormality, it is necessary to make a comprehensive judgment based on the working time and working life of the transformer.
JIANGYIN LIYI ELECTRONICS
Add:Add,No 444 Chengyang Road,Yunting Town,
Jiangyin City,Jiangsu Province
Tel:+86-0510-88617657 , 88617670
E-mail:wuqiyi@liyidz.com
FLOLLOW US

Copyright © 2022 JIANGYIN LIYI ELECTRONICS TECHNOLOGY CO.,LTD 苏ICP备18020572号-1 Powered By www.300.cn | SEO